! Microenvironment Descriptions for an APEX application with 8 microenvironments for APEX/MSS paper (8/30/18)

! First Section - Microenvironment Descriptions

Micro      Name                                              Method
1          Indoor-Residential                                MASSBAL
2          Indoor-Office_bldg_Hospital                       MASSBAL
3          Indoor-School                                     MASSBAL
4          Indoor-Stores_Other                               MASSBAL
5          Indoor-Restaurant                                 MASSBAL
6          Outdoor-General                                   FACTORS
7          Outdoor-Near_road                                 FACTORS
8          In_vehicle                                        FACTORS

! Second Section - Parameter Descriptions

!  AIR EXCHANGE RATES FOR INDOOR RESIDENCE
MP#               = 1
SobolGroup        = 16
Micro number      = 1
Parameter Type    = AER
Condition # 1     = AvgTempCat
Condition # 2     = AC_Home   ! yes/no
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES

Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.744   1.982  0   .    0.1    10      Y  
1     1     1      1     2   1   1   Lognormal   0.811   2.653  0   .    0.1    10      Y  
1     1     1      1     3   1   1   Lognormal   0.785   2.817  0   .    0.1    10      Y  
1     1     1      1     4   1   1   Lognormal   0.916   2.671  0   .    0.1    10      Y  
1     1     1      1     1   2   1   Lognormal   0.760   1.747  0   .    0.1    10      Y  
1     1     1      1     2   2   1   Lognormal   1.447   2.950  0   .    0.1    10      Y  
1     1     1      1     3   2   1   Lognormal   1.531   2.472  0   .    0.1    10      Y  
1     1     1      1     4   2   1   Lognormal   1.901   2.524  0   .    0.1    10      Y  


!  AIR EXCHANGE RATES FOR INDOOR-Office buildings/Hospitals
MP#               = 2
SobolGroup        = 16
Micro number      = 2
Parameter Type    = AER
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape      Values
1     1     1      1     1   1   1   LogNormal   1.109  3.015  0    .    0.07   13.8    Y  

!  AIR EXCHANGE RATES FOR INDOOR-School
MP#               = 3
SobolGroup        = 16
Micro number      = 3
Parameter Type    = AER
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape      Values
1     1     1      1     1   1   1   Weibull    1.26    1.75    0    .    0.1    10    Y  

!  AIR EXCHANGE RATES FOR INDOOR-OTHER (Stores/other)
MP#               = 4
SobolGroup        = 16
Micro number      = 4
Parameter Type    = AER
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape      Values
1     1     1      1     1   1   1   LogNormal   1.109  3.015  0    .    0.07   13.8    Y  

!  AIR EXCHANGE RATES FOR INDOOR-Restaurants  Distribution from Bennett data (6 values)
MP#               = 5
SobolGroup        = 16
Micro number      = 5
Parameter Type    = AER
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape      Values
1     1     1      1     1   1   1   LogNormal   3.712  1.855  0    .    1.46   9.07    Y  


!  DECAY RATES FOR OZONE

MP#               = 6
SobolGroup        = 16
Micro number      = 1
Pollutant         = 1
Parameter Type    = DE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   LogNormal   2.51   1.53   0    .    0.95   8.05    Y   

MP#               = 7
SobolGroup        = 16
Micro number      = 2
Pollutant         = 1
Parameter Type    = DE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   LogNormal   2.51   1.53   0    .    0.95   8.05    Y   

MP#               = 8
SobolGroup        = 16
Micro number      = 3
Pollutant         = 1
Parameter Type    = DE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   LogNormal   2.51   1.53   0    .    0.95   8.05    Y   

MP#               = 9
SobolGroup        = 16
Micro number      = 4
Pollutant         = 1
Parameter Type    = DE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   LogNormal   2.51   1.53   0    .    0.95   8.05    Y   

MP#               = 10
SobolGroup        = 16
Micro number      = 5
Pollutant         = 1
Parameter Type    = DE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   LogNormal   2.51   1.53   0    .    0.95   8.05    Y   

! PROXIMITY FACTORS FOR INDOOR MEs
MP#               = 11
SobolGroup        = 16
Micro number      = 1
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

MP#               = 12
SobolGroup        = 16
Micro number      = 2
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

MP#               = 13
SobolGroup        = 16
Micro number      = 3
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

MP#               = 14
SobolGroup        = 16
Micro number      = 4
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

MP#               = 15
SobolGroup        = 16
Micro number      = 5
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

! PROXIMITY FACTORS FOR OUTDOOR-GENERAL
MP#               = 16
SobolGroup        = 16
Micro number      = 6
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = YES
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Lognormal   0.988  1.689   0    .      0.5    1.5    Y  

! PROXIMITY FACTORS FOR OUTDOOR-NEAR ROAD
MP#               = 17
SobolGroup        = 16
Micro number      = 7
Pollutant         = 1
Parameter Type    = PR
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Normal      0.755  0.203   .     .   0.422  1.0     Y  

! PROXIMITY FACTORS FOR OZONE - OUTDOOR-In Vehicle
MP#               = 18
SobolGroup        = 16
Micro number      = 8
Pollutant         = 1
Parameter Type    = PR
Condition # 1     = DailyConditional1
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Normal      0.755  0.203  .    .    0.422  1.0     Y 
1     1     1      1     2   1   1   Normal      0.754  0.243  .    .    0.355  1.0     Y 
1     1     1      1     3   1   1   Normal      0.364  0.165  .    .    0.093  1.0     Y 

! PENETRATION FACTORS FOR OZONE - In-Vehicle
MP#               = 19
SobolGroup        = 16
Micro number      = 8
Pollutant         = 1
Parameter Type    = PE
ResampHours       = NO
ResampDays        = NO
ResampWork        = YES
Block DType Season Area C1  C2  C3   Shape       Par1   Par2  Par3 Par4  LTrunc UTrunc  ResampOut
1     1     1      1     1   1   1   Normal      0.300  0.232  .    .    0.1    1.0     Y 